CVE-2025-14097 - CVE House
Back to Database
Status published High CVE-2025-14097

Remote Code Execution Vulnerability in Radiometer Products

Vulnerability Description

A vulnerability in the application software of multiple Radiometer products may allow remote code execution and unauthorized device management when specific internal conditions are met. Exploitation requires that a remote connection is established with additional information obtained through other means. The issue is caused by a weakness in the analyzer’s application software.                                                                                                                                                                                                Other related CVE's are CVE-2025-14095 & CVE-2025-14096.                                                                                                      Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency. Required Configuration for Exposure: Affected application software version is in use and remote support feature is enabled in the analyzer.                                                                                                                                                                        Temporary work Around: If the network is not considered secure, please remove the analyzer from the network.                         Permanent solution: Customers should ensure the following: • The network is secure, and access follows best practices. Local Radiometer representatives will contact all affected customers to discuss a permanent solution.                                                      Exploit Status: Researchers have provided working proof-of-concept (PoC). Radiometer is not aware of any publicly available exploits at the time of this publication.

Impact Analysis

Refer to official advisory for detailed impact metrics.

Remediation

Ensure systems are updated to the latest vendor-supplied patch levels.

THREAT MONITOR

Am I Vulnerable?

Launch our assessment wizard to check if your infrastructure is exposed to • CVE-2025-14097

Credits & Attribution

The following person or organization is credited with identifying this vulnerability, as recorded in the NVD database:

  • Florian Hauser and Fabian Weber from CODE WHITE GmbH

Affected Vendor

Radiometer Medical Aps

View all reports →

Affected Software

ABL90 FLEX and ABL90 FLEX PLUS Analyzers, ABL800 BASIC and ABL800 FLEX Analyzers, AQT90 FLEX Analyzers
Vulnerable Versions:
Application software versions < 3.5MR11 with Windows 7, Windows XP operating systems, Application software versions >= 3.5MR11 with Windows 10 operating system, Application software versions < 6.20MR2 with Windows 7, Windows XP operating systems, Application software versions >= 6.20MR2 with Windows 10 operating system, Application software versions <= 8.13 MR2 with Windows 7, Windows XP operating systems, Application software versions >= 8.13 MR2 with Windows 10 operating system

Timeline

Official Publish: December 17th, 2025
Last Modified: December 17th, 2025
Added to House: July 22nd, 2026

CVSS Vectors

V3: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Weaknesses (CWE)