Out-of-bounds read when processing a received IPv6 packet

Vulnerability Description

Contiki-NG is an operating system for internet-of-things devices. In versions 4.9 and prior, when a packet is received, the Contiki-NG network stack attempts to start the periodic TCP timer if it is a TCP packet with the SYN flag set. But the implementation does not first verify that a full TCP header has been received. Specifically, the implementation attempts to access the flags field from the TCP buffer in the following conditional expression in the `check_for_tcp_syn` function. For this reason, an attacker can inject a truncated TCP packet, which will lead to an out-of-bound read from the packet buffer. As of time of publication, a patched version is not available. As a workaround, one can apply the changes in Contiki-NG pull request #2510 to patch the system.

Impact Analysis

Refer to official advisory for detailed impact metrics.

Remediation

Ensure systems are updated to the latest vendor-supplied patch levels.

THREAT MONITOR

Am I Vulnerable?

Launch our assessment wizard to check if your infrastructure is exposed to • CVE-2023-37459

Credits & Attribution

No credits recorded in the NVD database.

Affected Vendor

Affected Software

contiki-ng
Vulnerable Versions:
<= 4.9

Timeline

Official Publish: September 15th, 2023
Last Modified: September 25th, 2024
Added to House: July 22nd, 2026

CVSS Vectors

V3: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N

Weaknesses (CWE)