CVE-2020-10276 - CVE House
Back to Database
Status published Critical CVE-2020-10276

RVD#2558: Default credentials on SICK PLC allows disabling safety features

Vulnerability Description

The password for the safety PLC is the default and thus easy to find (in manuals, etc.). This allows a manipulated program to be uploaded to the safety PLC, effectively disabling the emergency stop in case an object is too close to the robot. Navigation and any other components dependent on the laser scanner are not affected (thus it is hard to detect before something happens) though the laser scanner configuration can also be affected altering further the safety of the device.

Impact Analysis

Refer to official advisory for detailed impact metrics.

Remediation

Ensure systems are updated to the latest vendor-supplied patch levels.

THREAT MONITOR

Am I Vulnerable?

Launch our assessment wizard to check if your infrastructure is exposed to • CVE-2020-10276

Credits & Attribution

The following person or organization is credited with identifying this vulnerability, as recorded in the NVD database:

  • Bernhard Dieber (Joanneum Research)

Affected Vendor

Mobile Industrial Robots A/S

View all reports →

Affected Software

MiR100
Vulnerable Versions:
v2.8.1.1 and before

Timeline

Official Publish: June 24th, 2020
Last Modified: September 16th, 2024
Added to House: July 21st, 2026

CVSS Vectors

V3: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H