An issue was discovered on Sigma Design Z-Wave S0 through...
Vulnerability Description
An issue was discovered on Sigma Design Z-Wave S0 through S2 devices. An attacker first prepares a Z-Wave frame-transmission program (e.g., Z-Wave PC Controller, OpenZWave, CC1110, etc.). Next, the attacker conducts a DoS attack against the Z-Wave S0 Security version product by continuously sending divided "Nonce Get (0x98 0x81)" frames. The reason for dividing the "Nonce Get" frame is that, in security version S0, when a node receives a "Nonce Get" frame, the node produces a random new nonce and sends it to the Src node of the received "Nonce Get" frame. After the nonce value is generated and transmitted, the node transitions to wait mode. At this time, when "Nonce Get" is received again, the node discards the previous nonce value and generates a random nonce again. Therefore, because the frame is encrypted with previous nonce value, the received normal frame cannot be decrypted.
Impact Analysis
Refer to official advisory for detailed impact metrics.
Remediation
Ensure systems are updated to the latest vendor-supplied patch levels.
Am I Vulnerable?
Launch our assessment wizard to check if your infrastructure is exposed to • CVE-2018-19983
Credits & Attribution
No credits recorded in the NVD database.
References
More from silabs
View All →Affected Vendor
silabs
View all reports →Affected Software
Timeline
CVSS Vectors
Weaknesses (CWE)
No CWE data available
MITRE ATT&CK TTPs
No associated TTPs found for this vulnerability.