CVE-2017-9855 - CVE House
Back to Database
Status published Unknown CVE-2017-9855

An issue was discovered in SMA Solar Technology products. A...

Vulnerability Description

An issue was discovered in SMA Solar Technology products. A secondary authentication system is available for Installers called the Grid Guard system. This system uses predictable codes, and a single Grid Guard code can be used on any SMA inverter. Any such code, when combined with the installer account, allows changing very sensitive parameters. NOTE: the vendor reports that Grid Guard is not an authentication feature; it is only a tracing feature. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected

Impact Analysis

Refer to official advisory for detailed impact metrics.

Remediation

Ensure systems are updated to the latest vendor-supplied patch levels.

THREAT MONITOR

Am I Vulnerable?

Launch our assessment wizard to check if your infrastructure is exposed to • CVE-2017-9855

Credits & Attribution

No credits recorded in the NVD database.

Affected Vendor

Affected Software

sunny boy 3600 firmware, sunny boy 5000 firmware, sunny tripower core1 firmware, sunny tripower 15000tl firmware, sunny tripower 20000tl firmware, sunny tripower 25000tl firmware, sunny tripower 5000tl firmware, sunny tripower 12000tl firmware, sunny tripower 60 firmware, sunny boy 3000tl firmware, sunny boy 3600tl firmware, sunny boy 4000tl firmware, sunny boy 5000tl firmware, sunny boy 1.5 firmware, sunny boy 2.5 firmware, sunny boy 3.0 firmware, sunny boy 3.6 firmware, sunny boy 4.0 firmware, sunny boy 5.0 firmware, sunny central 2200 firmware, sunny central 1000cp xt firmware, sunny central 800cp xt firmware, sunny central 850cp xt firmware, sunny central 900cp xt firmware, sunny central 500cp xt firmware, sunny central 630cp xt firmware, sunny central 720cp xt firmware, sunny central 760cp xt firmware, sunny central storage 500 firmware, sunny central storage 630 firmware, sunny central storage 720 firmware, sunny central storage 760 firmware, sunny central storage 800 firmware, sunny central storage 850 firmware, sunny central storage 900 firmware, sunny central storage 1000 firmware, sunny central storage 2200 firmware, sunny central storage 2500-ev firmware, sunny boy storage 2.5 firmware
Vulnerable Versions:
Unknown

Timeline

Official Publish: August 5th, 2017
Last Modified: October 29th, 2024
Added to House: July 20th, 2026

CVSS Vectors

No vector data available

Weaknesses (CWE)

No CWE data available

MITRE ATT&CK TTPs

No associated TTPs found for this vulnerability.