CVE-2017-6015 - CVE House
Back to Database
Status published High CVE-2017-6015

Without quotation marks, any whitespace in the file path for...

Vulnerability Description

Without quotation marks, any whitespace in the file path for Rockwell Automation FactoryTalk Activation version 4.00.02 remains ambiguous, which may allow an attacker to link to or run a malicious executable. This may allow an authorized, but not privileged local user to execute arbitrary code with elevated privileges on the system. CVSS v3 base score: 8.8, CVSS vector string: (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). Rockwell Automation has released a new version of FactoryTalk Activation, Version 4.01, which addresses the identified vulnerability. Rockwell Automation recommends upgrading to the latest version of FactoryTalk Activation, Version 4.01 or later.

Impact Analysis

Refer to official advisory for detailed impact metrics.

Remediation

Ensure systems are updated to the latest vendor-supplied patch levels.

THREAT MONITOR

Am I Vulnerable?

Launch our assessment wizard to check if your infrastructure is exposed to • CVE-2017-6015

Credits & Attribution

No credits recorded in the NVD database.

Affected Vendor

Rockwell Automation

View all reports →

Affected Software

FactoryTalk Activation
Vulnerable Versions:
FactoryTalk Activation Service, Version 4.00.02 and prior versions.

Timeline

Official Publish: May 11th, 2018
Last Modified: September 16th, 2024
Added to House: July 20th, 2026

CVSS Vectors

V3: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Weaknesses (CWE)