Status published High CVE-2015-3952

Wireless keys are stored in plain text on Hospira Plum...

Vulnerability Description

Wireless keys are stored in plain text on Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior. Hospira recommends that customers close Port 20/FTP and Port 23/TELNET on the affected devices. Hospira has also released the Plum 360 Infusion System which is not vulnerable to this issue.

Impact Analysis

Refer to official advisory for detailed impact metrics.

Remediation

Ensure systems are updated to the latest vendor-supplied patch levels.

THREAT MONITOR

Am I Vulnerable?

Launch our assessment wizard to check if your infrastructure is exposed to • CVE-2015-3952

Credits & Attribution

No credits recorded in the NVD database.

Affected Vendor

Affected Software

Plum A+ Infusion System, Plum A+3 Infusion System, Symbiq Infusion System
Vulnerable Versions:
<= 13.4, <= 13.6, <= 3.13

Timeline

Official Publish: March 25th, 2019
Last Modified: August 6th, 2024
Added to House: July 19th, 2026

CVSS Vectors

V3: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

Weaknesses (CWE)