Status published Critical CVE-2009-3027

VRTSweb.exe in VRTSweb in Symantec Backup Exec Continuous Protection Server...

Vulnerability Description

VRTSweb.exe in VRTSweb in Symantec Backup Exec Continuous Protection Server (CPS) 11d, 12.0, and 12.5; Veritas NetBackup Operations Manager (NOM) 6.0 GA through 6.5.5; Veritas Backup Reporter (VBR) 6.0 GA through 6.6; Veritas Storage Foundation (SF) 3.5; Veritas Storage Foundation for Windows High Availability (SFWHA) 4.3MP2, 5.0, 5.0RP1a, 5.0RP2, 5.1, and 5.1AP1; Veritas Storage Foundation for High Availability (SFHA) 3.5; Veritas Storage Foundation for Oracle (SFO) 4.1, 5.0, and 5.0.1; Veritas Storage Foundation for DB2 4.1 and 5.0; Veritas Storage Foundation for Sybase 4.1 and 5.0; Veritas Storage Foundation for Oracle Real Application Cluster (SFRAC) 3.5, 4.0, 4.1, and 5.0; Veritas Storage Foundation Manager (SFM) 1.0, 1.0 MP1, 1.1, 1.1.1Ux, 1.1.1Win, and 2.0; Veritas Cluster Server (VCS) 3.5, 4.0, 4.1, and 5.0; Veritas Cluster Server One (VCSOne) 2.0, 2.0.1, and 2.0.2; Veritas Application Director (VAD) 1.1 and 1.1 Platform Expansion; Veritas Cluster Server Management Console (VCSMC) 5.1, 5.5, and 5.5.1; Veritas Storage Foundation Cluster File System (SFCFS) 3.5, 4.0, 4.1, and 5.0; Veritas Storage Foundation Cluster File System for Oracle RAC (SFCFS RAC) 5.0; Veritas Command Central Storage (CCS) 4.x, 5.0, and 5.1; Veritas Command Central Enterprise Reporter (CC-ER) 5.0 GA, 5.0 MP1, 5.0 MP1RP1, and 5.1; Veritas Command Central Storage Change Manager (CC-SCM) 5.0 and 5.1; and Veritas MicroMeasure 5.0 does not properly validate authentication requests, which allows remote attackers to trigger the unpacking of a WAR archive, and execute arbitrary code in the contained files, via crafted data to TCP port 14300.

Impact Analysis

Refer to official advisory for detailed impact metrics.

Remediation

Ensure systems are updated to the latest vendor-supplied patch levels.

THREAT MONITOR

Am I Vulnerable?

Launch our assessment wizard to check if your infrastructure is exposed to • CVE-2009-3027

Credits & Attribution

No credits recorded in the NVD database.

Affected Vendor

Affected Software

backup exec continuous protection server, veritas application director, veritas backup exec, veritas cluster server, veritas cluster server management console, veritas cluster server one, veritas command central enterprise reporter, veritas command central storage, veritas command central storage change manager, veritas micromeasure, veritas netbackup operations manager, veritas netbackup reporter, veritas storae foundation, veritas storage foundation, veritas storage foundation cluster file system, veritas storage foundation cluster file system for oracle rac, veritas storage foundation for db2, veritas storage foundation for high availability, veritas storage foundation for oracle, veritas storage foundation for oracle real application cluster, veritas storage foundation for sybase, veritas storage foundation for windows high availability, veritas storage foundation manager
Vulnerable Versions:
11d, 12.0, 12.5, 1.1, 3.5, 4.0, 4.1, 5.0, 5.1, 5.5, 5.5.1, 2.0, 2.0.1, 2.0.2, 5.0_ga, 5.0mp1, 5.0mp1rp1, 4.x, 6.0_ga, 6.5.5, 6.6, 3.5_onwards, 5.0.1, 4.3mp2, 5.0rp1a, 5.0rp2, 5.1ap1, 1.0, 1.0mp1, 1.1.1ux, 1.1.1win

Timeline

Official Publish: December 11th, 2009
Last Modified: August 7th, 2024
Added to House: July 19th, 2026

CVSS Vectors

Weaknesses (CWE)

No CWE data available

MITRE ATT&CK TTPs

No associated TTPs found for this vulnerability.